The 400A & 400A-3 can be used to switch voltage between 0-250V.
Generally only if the load is less than 10W to prevent flickering.
Not required.
Yes, Energy Sense range of master timers can be linked with the full range of activators i.e Push Button,Touch & PIR for 2 way switching.
Energy standard is rated at 10A and the Energy Sense is rated at 16A with additional features such as blue and red LED indicator and screwless covers.
The 2 wire require only a Live in & Live out only, the 3 wire require Live in, Live out & Neutral.
Not recommended, instead use any Elkay 3 wire timer.
Elkay have the only 2 wire electronic switch in the world that can switch a contactor. This is the 400NE Electronic Columbus Timer and can switch up to 5A of load. A capacitor is required at the A1 and A2 (switch live and neutral of the contactor) points of the contactor. No other Elkay 2 wire switch is capable of this so if you require an alternative then you can also use the 3 wire electronic timers from our range instead.
Not recommended, instead use any Elkay 3 wire timer.
Use any Elkay 3 wire Timer and a 20A 32A or 40A contactor with our Timer switching the contactor coil. This will need a capaitor at the A1 and A2 points of the contacor and Elkay have specific wiring drawings to help you with this.
Any Elkay Timer can be used providing it is located outside Zone 2. If inside the Zones use our Outdoor products. Ceiling Mount PIRs can be used in Zones 1 and 2 provided that the ceiling is 2.25m from the finished floor level.
Use any Elkay 3 wire Timer and a 20A 32A or 40A contactor with our Timer switching the contactor coil. This will need a capaitor at the A1 and A2 points of the contacor and Elkay have specific wiring drawings to help you with this.
Any Elkay 3 wire timer is suitable plus the new 400NE Columbus Electronic timer which is the worlds first electronic timer that can switch a contactor.
NO – It is not generally required with many of our products just when using 2 wire electronic products with low wattage loads but is available if required with the part code (PFCC-1).
NO – It is not generally required with many of our products just when using 2 wire electronic products with low wattage loads but is available if required with the part code (PFCC-1).
3 wire Push Button, Touch and PIR available in Brushed Stainless Steel.
The 400A – Has a Normally Closed (NC) and a Normally Open (NO) terminal for this application.
The 400A & 400A-3 can be used to switch 110V.
Elkay outdoor range timers are suitable for all outdoor application and are supplied with a back box and the relevant sealing components to achieve IP66 rating when suitable cable glands are used.
NO, this feature cannot be disabled, alternative Elkay energy standrd range without LEDs are available and recommended for bedrooms or ensuites.
Maximum lamp load is 10A.
Maximum lamp load is 16A.
Our Outdoor range is rated at IP66 and is the highest rated ouitdoor timeswitch on the market.
It means that our electronic products can switch any Resitive, Incandescent, Inductive, Flourescent or LED load at theFULL amp rating without the need to derate. This is unque to Elkay in the timeswitch market and makes life easier for installers and wholesaler trade counter staff.
You can use many options with Elkay. Lets assume you have a standard two way arrangement with a common and two strappers- in this case you could use a master and an activator product. So for Push you would use 350A-1 and 350A-3, for Touch you would use 360A-1 and 360A-3, for PIR you could use 376A-1 and 376A-3. Dont forget for low wattage LED loads use a capacitor PFCC-1.
It’s the same as above as you just add another activator in the intermediate position so for Push 350A-1 and 2 x 350A-3; for Touch use 360A-1 and 2 x 360A-3; for PIR use 376A-1 and 2x 376A-3. Dont forget for low wattage LED loads use a capacitor PFCC-1. Dont forget for low wattage LED loads use a capacitor PFCC-1.
There is no such thing as a intermediate time switch – Replace the intermediate switch with an additional activator and see points 25 and 26 above.
Then you can use either our Columbus Pneumatic 400A or Electronic Timers 400NE or use our Standard Push button 350B-1 or our Standard PIR 376B-1. You can wire multiple units together in these products so for 3 switches in a circuit use 3 x 350B-1. These products were specifically designed for this purpose. Dont forget for low wattage LED loads use a capacitor PFCC-1.
Yes but ensure that the switches are all activators or momentary switches.
Yes we do and these are as follows;
370A-1 PIR Timer Master 3 wire, 376A-1 2 Wire PIR Timer Master 2 Wire, 370B-1 Standard PIR Timer 3 wire 376B-1 Standard PIR Timer 2 wire, 374B-1 All in One Ceiling Occupancy Sensor, 374C-1 Flush Mount Occupancy Sensor, 380A-1 Microwave Sensoe, 570A-1 Outdoor PIR Timer IP66